Fast Combined Charge Solution (82kW) (CCS CHAdeMO & AC Type-2)
Technical Specifications
Power
Input |
Input Voltage 415VAC; 3-phase/L1, L2, L3, N, PE |
Input Voltage Range 320VAC to 530VAC | |
Input Frequency Range 45Hz-60Hz | |
Power Factor >0.98 | |
Efficiency ≥95% | |
Max. Output Power 142kW (120Kw DC, 22Kw AC) |
Power
Output |
DC Output 1 CCS 2, 200-750 VDC |
DC Output 2 CHAdeMO, 200-750 VDC | |
AC Output Type 2, AC 3 phase, 22kW max. | |
Charging Operation Cyclic Mode/Parallel Mode |
Protection & Safety |
Over current, Under voltage, Over voltage, Residual current,
Protections Surge protection, Short circuit, Over temperature, Ground fault, Insulation fault, Emergency Stop etc. |
Communi- cation |
Charger & Ethernet (standard); 4G Fallback 3G (optional)- OCPP Central Server v1.6 |
Charger & Vehicle CAN (CHAdeMO), PLC (CCS), PWM (AC Type 2).
As per IEC/EN 61851-1 |
|
Language English |
User Interface &
Control |
Display 7” TFT LCD Touch screen |
Push Button Mushroom Type Emergency stop switch (Red) | |
Visual Indication Error indicator, Presence of input supply,
State of charger indicator |
|
Charge options Auto Charge, Mode Selection (Time/Amount/Power/SOC) | |
Charging Mode Mode 4 for DC charging; Mode 3 for AC charging
(as per IEC/EN 61851-1) |
Authentica- tion |
User Authentication RFID/APP/OTP/QR (as per requirement) |
Environment |
Operating Temperature -20°C to 75°C (derating from 50°C) |
Storage Temperature -20°C to 80°C | |
Humidity 5% to 95% non-condensing |
Mechanical |
IP Rating IP 54 |
Cooling Forced cooling | |
Dimensions (H x W x D) (mm) 1600x650x500 | |
Charging Cable length 5 meters |