60kW to 200kW CCS Type 2 Chargers

Technical Specifications

Power

Output

DC output voltage rating                                    200-750VDC
 

Output Current                          125A/200A                200A Max.                  300A Max.

(200A Max. per gun)

Power Rating                               30-80kW           90-120kW                    150-200kW
Connector                                    Output connector with GB/T 20234.3 Compliance
Number of Guns                            1/2                       1/2                                     2
Efficiency                                                                      ≥94%
Power

Input

                                                        3Ø, 415V (+6% and-10%)

Input Voltage                       3-Phase, 5 Wire AC system (3Ph+N+E)                                    

Input Frequency                                        50Hz, ±5Hz
THD                                                             ≤ 5% @Normal Voltage
Power factor                                               ≥ 0.99 (Full load)
Protection &

Safety

                                       Over current, Under voltage, Over voltage

Safety Parameters                         Surge protection, Short circuit, Over temperature

User Interface &

Control

Display                                                   7” TFT LCD Touch screen
Support language                                                English
Push Button                                     Mushroom Type Emergency stop switch (Red)
Charge Option                                           Grid responsive metering
Visual Indication                             Error indicator, Presence of input supply,

State of charger indicator

User Authentication                       ISO/IEC 14443 A RFID for user authentication
 

Communi-

   cation

B/w EVSE and Vehicle                        PLC based Communication as per DIN 70121
B/w charger and                                    OCPP v1.6-10/100 Base-T Ethernet (Standard)/

Central Server                                           Optional GSM Modem (4G Fallback 3G)

 

 

Mechanical

Ingress Protection                                             IP 54
Cooling                                                        Forced Air cooling
Dimensions (H x W x D) (mm)      1600x650x500            1800x650x500           1800x800x500
Charging Cable length                  5 meters
 

Environment 

Operating Temperature               -20°C to 75°C (derating from 50°C)
Humidity (Non-condensing)            0 to 95%
Storage Temperature                    -20°C to 80°C